by G4EML
Tue Dec 03, 2019 5:32 pm
Forum: GD-77 / DM-1801 / RD-5R / GD-77S
Topic: Disable Private Call notification for special IDs
Replies: 9
Views: 5041

Re: Disable Private Call notification for special IDs

Roger, I have just tested this. The current firmware is incorrectly responding to a private call to any ID and displaying the 'Accept Call' prompt. It should only be triggered by a private call to its own ID. I looks like there is no filtering to test if the destination ID is the radios ID. What IU4...
by G4EML
Tue Dec 03, 2019 4:48 pm
Forum: Hotspot mode
Topic: BER and Duty Cycle
Replies: 8
Views: 5060

Re: BER and Duty Cycle

I don't think RxOffset or TxOffset would be needed for the OpenGD77. DMR Radios can talk to each other without the need for constant fine tuning. That was something that became necessary as a work-around for problems with the Hotspot hardware which are not present in the GD77. For the same reason MM...
by G4EML
Tue Dec 03, 2019 1:14 pm
Forum: Hotspot mode
Topic: BER and Duty Cycle
Replies: 8
Views: 5060

Re: BER and Duty Cycle

A properly implemented DMR decoder in a custom designed chip as used in the GD77 and other DMR radios is tolerant of quite large frequency errors, indeed this is a requirement to fully comply with the DMR specifications. Hotspots have always been excessively sensitive to fine tuning of the frequency...
by G4EML
Sun Dec 01, 2019 10:44 pm
Forum: General discussions
Topic: [Solved] Scanning Problem
Replies: 13
Views: 7728

Re: [Solved] Scanning Problem

At the moment it’s just

‘Auto scan’ becomes ‘Zone Skip’
‘Lone Worker’ becomes ‘All Skip’

Some of the other items (like Scan Lists) are redundant in openGD77 but there is probably no harm in leaving them there for now.
by G4EML
Sun Dec 01, 2019 12:43 pm
Forum: Off topic
Topic: keys and buttons
Replies: 62
Views: 42077

Re: keys and buttons

Don’t forget Function + up down = Change Zone.
by G4EML
Sun Dec 01, 2019 11:29 am
Forum: General discussions
Topic: [Solved] Scanning Problem
Replies: 13
Views: 7728

Re: Scanning Problem

We are doing many things in a different way to the official CPS. Therefore the functions of some of the codeplug items are different. Scanning is one of those differences. We are using the ‘auto scan’ flag as ‘zone scan skip this channel’ and the ‘lone worker’ flag as ‘all scan skip this channel’. T...
by G4EML
Sat Nov 30, 2019 6:08 pm
Forum: GD-77 / DM-1801 / RD-5R / GD-77S
Topic: compile the firmware
Replies: 9
Views: 5044

Re: compile the firmware

You need to install the MCUXpresso IDE . Downloadable from NXP.com
by G4EML
Sat Nov 30, 2019 12:56 pm
Forum: Localisation
Topic: Localisation support (foreign languages)
Replies: 921
Views: 361271

Re: Localistion support (foreign languages)

Scan settings have now changed to options menu. When Roger approves this change there will be three new strings added to all Language files. 'Scan Mode', 'Hold' and 'Pause'. I can see that maintaining these files will be time consuming for a while as we add new functions all the time. Translators wi...
by G4EML
Fri Nov 29, 2019 8:19 pm
Forum: General discussions
Topic: [Solved] Scanning Problem
Replies: 13
Views: 7728

Re: Scanning Problem

Your comment “(autoscan set for each channel)” might be significant. The auto scan tick box on the CPS has a different function in OpenGD77. It is used as a ‘skip channel’ flag. If this is set then the scan will skip over the channel and not stop. You can check and change the state of the flag by pr...
by G4EML
Tue Nov 26, 2019 10:56 am
Forum: GD-77 / DM-1801 / RD-5R / GD-77S
Topic: DMR filtering by CC TS and TG
Replies: 39
Views: 20244

Re: DMR filtering by CC TS and TG

Roger, Leaving monitor mode active on dual timeslot after transmitting could cause a lot of confusion with people potentially swapping time slots without realising. I would have thought that if you press the PTT the timeslot should be locked and Monitor mode should be reset to single timeslot. Prett...